Power Generation Technology ›› 2018, Vol. 39 ›› Issue (2): 153-157.DOI: 10.12096/j.2096-4528.pgt.2018.024

• Power Generation and Environmental Protection • Previous Articles     Next Articles

Analysis on Replacing of Smaller Bore Nozzles for Long-distance Water Soot Blower

Lixiong QIU1(),Li ZHANG2,Ming XIONG2,Yani ZHUANG2   

  1. 1 Shenhua Guohua(Beijing) Gas Thermal Power Co.LTD, Chaoyang District, Beijing 100024
    2 School of Automation, Beijing Information Science & Technology University, Haidian District, Beijing 100192, China
  • Received:2017-12-01 Published:2018-04-30 Online:2018-07-27
  • Supported by:
    National Natural Science Foundation of China(51377011)

Abstract:

Large scale wind power integration needs thermal generator regulate output power flexibly; during the reform of boiler for flexibility, the normal operation condition should be kept.To reduce the disturbance to the heat load of the boiler furnace, reduce the expansion of the boiler, and to protect the output power flexibly, the operation parameters of the boiler are studied.The long-distance water soot blower of #1 and #2 furnace in a power plant has larger flow rate and great influence on the boiler parameters during the blowing soot process.By replacing the smaller bore nozzle, the disturbance of the water soot blower to the boiler parameters was controlled.The comparison of operation parameters of the boiler before and after the replacement had proved that it is feasible and safe to change the bore nozzle by smaller diameter nozzle.

Key words: boiler, power regulation, long-distance water soot blower, small bore nozzles, parameters