Power Generation Technology ›› 2017, Vol. 38 ›› Issue (4): 40-42,39.DOI: 10.3969/J.ISSN.2095-3429.2017.04.009

Previous Articles     Next Articles

Analysis of FCB Control Strategy for 600MW Thermal Power Plant

QU Zhang-long, GUO Yan-hao   

  1. Huadian Electric Power Research Institute Xi'an Branch, Xi'an 710032, China
  • Received:2017-07-21 Revised:2017-08-22 Published:2017-08-30 Online:2017-08-30

Abstract: Thermal power plant fast cut back is an important safety guarantee of large units indispensable,through the analysis of main equipment and system of No. 3 unit of India KMPCLpower plant 6×600MW project,according to the control strategy of FCB control difficulty made fuel,steam flow, drum level and interlock protection,to ensure a successful test of fast cut back.

Key words: fuel, main steam flow, drum water level, interlock protection

CLC Number: