Power Generation Technology ›› 2019, Vol. 40 ›› Issue (6): 564-569.DOI: 10.12096/j.2096-4528.pgt.19096

• Power Generation and Environmental Protection • Previous Articles     Next Articles

Study on Generation, Hazard, Testing and Emission Characteristics of SO3 in Flue Gas of Coal-fired Power Plants

Zhaomei CHEN(),Hanxiao LIU*(),Ying CUI,Gaofei GUO(),Yincan MENG,Meiling LIU,Haitao HE,Xiaowei FANG   

  • Received:2019-06-08 Published:2019-12-31 Online:2019-12-31
  • Contact: Hanxiao LIU
  • Supported by:
    National Key Research and Development Program of China(2016YFC0209107);Zhejiang "Ten Thousand People Plan" Project(2017R52034)

Abstract:

The emission of non-conventional pollutants such as SO3 in the flue gas of coal-fired power plants has not been effectively controlled. Its hazards mainly include low-temperature corrosion, equipment blockage and environmental pollution, which mainly come from the combustion of coal. The content of Sar in 200 kinds of coal in China was statistically analyzed, the range is 0.11%-3.47%, the average value is 0.82%. The SO3 sampling methods mainly include control condensation and isopropanol absorption method. The combination of the two methods can significantly improve the capture rate of SO3 and the accuracy of test data. Based on field measurement and literature survey, the SO3 emission characteristics of existing coal-fired power plants were characterized, which can provide reference for future control of SO3 emission for coal-fired power plants.

Key words: coal-fired power plant, SO3 emission, ultra-low emission, test method