发电技术 ›› 2024, Vol. 45 ›› Issue (2): 233-239.DOI: 10.12096/j.2096-4528.pgt.24026

• 双碳背景下灵活性发电技术 • 上一篇    下一篇

深度调峰工况下超临界机组的干湿态转换策略研究

杨正, 孙亦鹏, 温志强, 程亮, 李战国   

  1. 华北电力科学研究院有限责任公司,北京市 西城区 100045
  • 收稿日期:2024-01-30 出版日期:2024-04-30 发布日期:2024-04-29
  • 作者简介:杨正(1990),男,博士,高级工程师,主要研究方向为锅炉炉内燃烧优化及调整、深度调峰诊断等,zbwzyangzheng@126.com
    孙亦鹏(1985),男,博士,教授级高级工程师,主要研究方向为锅炉灵活性改造评估、智慧电厂大数据分析等,syp1103@qq.com
    温志强(1979),男,硕士,高级工程师,主要研究方向为锅炉辅机适应性评估、环保一体化分析等,wen_zq@126.com
    程亮(1979),男,硕士,教授级高级工程师,主要研究方向为二十五项反措锅炉部分、火电灵活性提升等,chengliang79@126.com
    李战国(1983),男,硕士,高级工程师,主要研究方向为火电机组深度调峰及性能评价等,yunliuz@163.com
  • 基金资助:
    国家重点研发计划项目(2022YFB4100303-3)

Research on Dry-Wet Conversion Strategy of Supercritical Thermal Power Units Under Deep Peaking Condition

Zheng YANG, Yipeng SUN, Zhiqiang WEN, Liang CHENG, Zhanguo LI   

  1. North China Electric Power Research Institute, Xicheng District, Beijing 100045, China
  • Received:2024-01-30 Published:2024-04-30 Online:2024-04-29
  • Supported by:
    National Key Research and Development Program of China(2022YFB4100303-3)

摘要:

为寻求深度调峰工况下合适的干湿态转换方式,在2台超临界机组上,采用2种不同的干湿态转换策略,对协调控制方式下的干湿态转换及其对系统稳定性的影响进行了研究。结果表明:2种策略均能够实现协调方式下的干湿态转换,可以通过转态进行进一步的深调工作;通过煤、水协同控制或给水流量控制均可实现干湿态转换,但水煤比变化情况不同;干转湿过程中,受到2种策略的影响,系统稳定性(主汽温度、主汽压力)区别明显;在湿转干过程中,2种策略下的系统都表现出良好的稳定性。

关键词: 火电机组, 深度调峰, 干湿态转换, 协调控制, 系统稳定性

Abstract:

To seek applicable dry-wet conversion mode in deep peaking condition, two different dry-wet conversion strategies were performed on two supercritical thermal power units to study the dry-wet conversion under coordinated control mode and its impact on the system stability. The results show that both strategies could realize the dry-wet conversion under coordinated control mode and further deep peaking could proceed via the dry-wet conversion. Moreover, the dry-wet conversion could be conducted either by co-control of coal and water or by feedwater control, yet the coal-water ratio varied. During the dry-to-wet process, affected by the two strategies, the system stability (the temperature and pressure of the main steam) is changed from dry state to wet state. In contrast, the system stability for both strategies is proved qualified under the conversion from wet state to dry state.

Key words: thermal power units, deep peaking, dry-wet conversion, coordinated control, system stability