摘要:

为较全面表征低低温电除尘系统(FGC+ESP)对SO3减排特性,提出了一种低浓度SO3测试方法,即“2级控制冷凝+1级异丙醇吸收”采样法,可提高其测试数据的准确性。基于此,测定中试平台低低温电除尘系统(ESP入口90 ℃)的SO3脱除效率为96.15%。3个工程项目4组现场实测数据中,低低温电除尘系统对SO3脱除效率在69.1%~96.6%,分析并验证了低低温工况下飞灰颗粒对SO3的吸附、团聚机制。研究结果可为低低温电除尘技术的大规模推广应用及燃煤电厂SO3减排提供借鉴。

关键词: 燃煤电厂, 超低排放, 低低温电除尘系统, SO3测试方法, 脱除性能

Abstract:

In order to fully characterize the emission reduction performance of SO3 by low-low temperature electrostatic precipitator system (FGC+ESP), a method to test low-concentration SO3 was proposed, namely “two-stage controlled condensation + one-stage isopropanol absorption” sampling method, which can improve the accuracy of its test data. According to this method, in the pilot test, the SO3 removal efficiency of the low-low temperature electrostatic precipitator (LL-ESP) system (90 ℃ at ESP entrance) was 96.15%. In four groups of field measured data from three engineering projects, the SO3 removal efficiency of LL-ESP system was 69.1%-96.6%. The mechanism of SO3 adsorption and agglomeration by fly ash particles under low-low temperature conditions was verified. The study results can provide reference for the large-scale promotion and application of LL-ESP technology and SO3 emission reduction of coal-fired power plants.

Key words: coal-fired power plant, ultra-low emission, low-low temperature electrostatic precipitator system, SO3 test method, removal performance