Zhonghao DONG, Xiaofeng LU, Lichao SHI, Zengzeng YANG, Fansheng KONG, Peng WANG, Guoqiang LIN, Peng ZHAO. Influence of Thermal Inertia of Refractory Material in Furnace on the Peak Regulating Rate of Circulating Fluidized Bed Boiler[J]. Power Generation Technology, 2023, 44(4): 514-524.
分布位置 | 耐火防磨浇注料/mm | 耐火保温砖/mm | |
---|---|---|---|
炉膛 | 布风板 | 77 | — |
炉膛锥段 | 60 | — | |
屏式受热面 | 50 | — | |
旋风分离器 | 分离器入口 | 25 | — |
分离器筒段 | 25 | — | |
分离器锥段 | 25 | — | |
立管及回料阀 | 立管 | 150 | 250 |
回料阀 | 150 | 250 | |
返料腿 | 150 | 250 |
Tab. 1 Distribution of refractory materials for 300 MW subcritical CFB boiler
分布位置 | 耐火防磨浇注料/mm | 耐火保温砖/mm | |
---|---|---|---|
炉膛 | 布风板 | 77 | — |
炉膛锥段 | 60 | — | |
屏式受热面 | 50 | — | |
旋风分离器 | 分离器入口 | 25 | — |
分离器筒段 | 25 | — | |
分离器锥段 | 25 | — | |
立管及回料阀 | 立管 | 150 | 250 |
回料阀 | 150 | 250 | |
返料腿 | 150 | 250 |
参数 | 传统耐火材料 | 耐火保温砖 | 高导热耐火材料 |
---|---|---|---|
导热率λ/[W/(m⋅K)] | 1.5 | 0.093+0.000 16T | 12.55/900 ℃ 11.28/800 ℃ |
密度ρ/(kg/m3) | 2750 | 500 | 3 560 |
比热容cp /(kJ∙kg-1∙K-1) | 0.92+ 0.000 147T | 0.769+0.000 26T | 1.229/900 ℃ |
Tab. 2 Thermophysical properties of refractory materials
参数 | 传统耐火材料 | 耐火保温砖 | 高导热耐火材料 |
---|---|---|---|
导热率λ/[W/(m⋅K)] | 1.5 | 0.093+0.000 16T | 12.55/900 ℃ 11.28/800 ℃ |
密度ρ/(kg/m3) | 2750 | 500 | 3 560 |
比热容cp /(kJ∙kg-1∙K-1) | 0.92+ 0.000 147T | 0.769+0.000 26T | 1.229/900 ℃ |
部位 | 耐火防磨浇注料 | 耐火保温砖 | 总计 | |
---|---|---|---|---|
炉膛 | 布风板 | 27.53 | — | 166.46 |
炉膛锥段 | 115.17 | — | ||
屏式受热面 | 23.76 | — | ||
旋风分离器 | 分离器入口 | 37.81 | — | 151.49 |
分离器筒段 | 76.14 | — | ||
分离器锥段 | 37.57 | — | ||
立管及回料阀 | 立管 | 44.69 | 16.59 | 308.75 |
回料阀 | 30.11 | 10.95 | ||
返料腿 | 147.99 | 58.42 |
Tab. 3 Mass distribution of refractory materials for 300 MW subcritical CFB boiler
部位 | 耐火防磨浇注料 | 耐火保温砖 | 总计 | |
---|---|---|---|---|
炉膛 | 布风板 | 27.53 | — | 166.46 |
炉膛锥段 | 115.17 | — | ||
屏式受热面 | 23.76 | — | ||
旋风分离器 | 分离器入口 | 37.81 | — | 151.49 |
分离器筒段 | 76.14 | — | ||
分离器锥段 | 37.57 | — | ||
立管及回料阀 | 立管 | 44.69 | 16.59 | 308.75 |
回料阀 | 30.11 | 10.95 | ||
返料腿 | 147.99 | 58.42 |
参数 | 工况1 | 工况2 |
---|---|---|
耐火材料导热率λ/[W/(m⋅K)] | 1,1.2,2,3,4,5,10,15 | 1.2 |
炉侧换热系数hf/[W/(m2⋅K)] | 360 | 360 |
耐火材料厚度δr/mm | 60 | 30,40,50,60,70,80,90 |
耐火材料密度ρ/(kg/m3) | 2 750 | 2 750 |
耐火材料比热容cp /[J/(kg⋅K)] | 1 092 | 1 092 |
工质温度tb/℃ | 330 | 330 |
初始温度T1/℃ | 850 | 850 |
终止温度T2/℃ | 950 | 950 |
Tab. 4 Calculation working condition of influence factors of thermal inertia of refractory materials
参数 | 工况1 | 工况2 |
---|---|---|
耐火材料导热率λ/[W/(m⋅K)] | 1,1.2,2,3,4,5,10,15 | 1.2 |
炉侧换热系数hf/[W/(m2⋅K)] | 360 | 360 |
耐火材料厚度δr/mm | 60 | 30,40,50,60,70,80,90 |
耐火材料密度ρ/(kg/m3) | 2 750 | 2 750 |
耐火材料比热容cp /[J/(kg⋅K)] | 1 092 | 1 092 |
工质温度tb/℃ | 330 | 330 |
初始温度T1/℃ | 850 | 850 |
终止温度T2/℃ | 950 | 950 |
材料类型 | 锅炉运行工况 | 锅炉变负荷速率/ (%/min) | 耐火材料厚度/ mm |
---|---|---|---|
传统耐火材料 | 50%~100%,100%~50% | 1,2,3 | 60 |
高导热耐火材料 | 50%~100%,100%~50% | 1,2,3 | 60 |
Tab. 5 Thermal inertia calculation conditions of refractory materials in dense phase area of furnace
材料类型 | 锅炉运行工况 | 锅炉变负荷速率/ (%/min) | 耐火材料厚度/ mm |
---|---|---|---|
传统耐火材料 | 50%~100%,100%~50% | 1,2,3 | 60 |
高导热耐火材料 | 50%~100%,100%~50% | 1,2,3 | 60 |
参数 | 100% BRL | 75% BRL | 50% BRL |
---|---|---|---|
主蒸汽流量/(t/h) | 966 | 779 | 466 |
主蒸汽温度/℃ | 541 | 541 | 541 |
主蒸汽压力/MPa | 16.10 | 14.49 | 11.37 |
给水温度/℃ | 276 | 255 | 233 |
给水压力/MPa | 17.92 | 15.75 | 12.59 |
汽包压力/MPa | 17.51 | 15.46 | 12.37 |
炉膛密相区床温/℃ | 950 | 900 | 850 |
给煤量/(t/h) | 204.90 | 157.13 | 108.59 |
燃料低位发热量/(kJ/kg) | 13 498 | 13 498 | 13 498 |
Tab. 6 Operation parameters of 300 MW subcritical CFB boiler
参数 | 100% BRL | 75% BRL | 50% BRL |
---|---|---|---|
主蒸汽流量/(t/h) | 966 | 779 | 466 |
主蒸汽温度/℃ | 541 | 541 | 541 |
主蒸汽压力/MPa | 16.10 | 14.49 | 11.37 |
给水温度/℃ | 276 | 255 | 233 |
给水压力/MPa | 17.92 | 15.75 | 12.59 |
汽包压力/MPa | 17.51 | 15.46 | 12.37 |
炉膛密相区床温/℃ | 950 | 900 | 850 |
给煤量/(t/h) | 204.90 | 157.13 | 108.59 |
燃料低位发热量/(kJ/kg) | 13 498 | 13 498 | 13 498 |
Fig. 9 Change of influence coefficient of thermal inertia coal feeding of refractory materials in dense phase area with time during variable load process
1 | GU Y J, XU J, CHEN D C,et al .Overall review of peak shaving for coal-fired power units in China[J].Renewable and Sustainable Energy Reviews,2016,54:723-731. doi:10.1016/j.rser.2015.10.052 |
2 | XUE Y S, ZHENG Y Q, RAHMAN S .Proceedings of purple mountain forum 2019-international forum on smart grid protection and control[M].Singapore:Springer,2019. doi:10.1007/978-981-13-9783-7 |
3 | 王珏,廖溢文,韩文福,等 .碳达峰背景下抽水蓄能-风电联合系统建模及有功功率控制特性研究[J].水利水电技术,2021,52(9):172-181. doi:10.13928/j.cnki.wrahe.2021.09.018 |
WANG Y, LIAO Y W, HAN W F,et al .Modeling and active power control characteristics of pumped storage-wind hybrid power system in the context of peak carbon dioxide emission[J].Water Resources and Hydropower Engineering,2021,52(9):172-181. doi:10.13928/j.cnki.wrahe.2021.09.018 | |
4 | 王磊,牛耘依,孟娜,等 .考虑调峰与储能特性的抽蓄电站服务电网综合评价[J].电网与清洁能源,2022,38(5):135-142. doi:10.3969/j.issn.1674-3814.2022.05.018 |
WANG L, NIU Y Y, MENG N,et al .Comprehensive evaluation of pumped storage power plant serving grid considering peak regulation and energy storage[J].Power System and Clean Energy,2022,38(5):135-142. doi:10.3969/j.issn.1674-3814.2022.05.018 | |
5 | 魏文,姜飞,戴双凤,等 .计及需求侧储能事故备用风险与火电机组深度调峰的经济优化研究[J].电力系统保护与控制,2022,50(10):153-162. |
WEI W, JIANG F, DAI S F,et al .Economic optimization of deep peak regulation of thermal power units taking into account the risk of emergency storage on the demand side[J].Power System Protection and Control,2022,50(10):153-162. | |
6 | 于国强,刘克天,胡尊民,等 .大规模新能源并网下火电机组深度调峰优化调度[J].电力工程技术,2023,42(1):243-250. doi:10.12158/j.2096-3203.2023.01.029 |
YU G Q, LIU K T, HU Z M,et al .Optimal scheduling of deep peak regulation for thermal power units in power grid with large-scale new energy[J].Electric Power Engineering Technology,2023,42(1):243-250. doi:10.12158/j.2096-3203.2023.01.029 | |
7 | 张松岩,苗世洪,尹斌鑫,等 .考虑火电深度调峰的多类型储能经济性分析[J].电力建设,2022,43(1):132-142. doi:10.12204/j.issn.1000-7229.2022.01.015 |
ZHANG S Y, MIAO S H, YIN B X,et al .Economic analysis of multi-type energy storages considering the deep peak-regulation of thermal power units[J].Electric Power Construction,2022,43(1):132-142. doi:10.12204/j.issn.1000-7229.2022.01.015 | |
8 | 闫修峰,宗珂,何修年,等 .1 000 MW煤电机组调峰中汽温控制策略研究[J].发电技术,2022,43(3):518-522. doi:10.12096/j.2096-4528.pgt.21024 |
YAN X F, ZONG K, HE X N,et al .Research on steam temperature control strategy in peak regulation of 1 000 MW coal power unit[J].Power Generation Technology,2022,43(3):518-522. doi:10.12096/j.2096-4528.pgt.21024 | |
9 | 牛斌,李丽锋,孙倩,等 .超临界循环流化床机组全负荷段深度调峰方法研究[J].发电技术,2021,42(2):273-279. doi:10.12096/j.2096-4528.pgt.20024 |
NIU B, LI L F, SUN Q,et al .Research on the method of depth peaking at full load of supercritical circulating fluidized bed unit[J].Power Generation Technology,2021,42(2):273-279. doi:10.12096/j.2096-4528.pgt.20024 | |
10 | 宋畅,吕俊复,杨海瑞,等 .超临界及超超临界循环流化床锅炉技术研究与应用[J].中国电机工程学报,2018,38(2):338-347. |
SONG C, LYU J F, YANG H R,et al .Research and application of supercritical and ultra-supercritical circulating fluidized bed boiler technology[J].Proceedings of the CSEE,2018,38(2):338-347. | |
11 | 蔡晋,单露,王志宁,等 .超临界350 MW循环流化床锅炉变负荷特性[J].热力发电,2020,49(9):98-103. doi:10.19666/j.rlfd.202002012 |
CAI J, SHAN L, WANG Z N,et al .Variable load characteristics of a supercritical 350 MW circulating fluidized bed boiler[J].Thermal Power Generation,2020,49(9):98-103. doi:10.19666/j.rlfd.202002012 | |
12 | 张绪辉,杨兴森,辛刚,等 .燃煤火电机组深度调峰运行试验[J].洁净煤技术,2022,28(4):144-150. |
ZHANG X H, YANG X S, XIN G,et al .Experimental study on deep peak regulation operation of coal-fired thermal power unit[J].Clean Coal Technology,2022,28(4):144-150. | |
13 | 杨中智,卢啸风,角加艺,等 .大型CFB锅炉低负荷再热汽温稳定特性研究[J].洁净煤技术,2023,29(6):32-39. |
YANG Z Z, LU X F, JIAO J Y,et al .Study on temperature stability characteristics of low load reheat steam in large CFB boiler[J].Clean Coal Technology,2023,29(6):32-39. | |
14 | 洪烽 .基于蓄能深度利用的循环流化床机组动态优化控制[D].北京:华北电力大学,2019. |
HONG F .Dynamic optimal control of criculating fluidized bed unit based on deep utilization of stored energy[D].Beijing:School of Energy Power and Mechanical Engineering,2019. | |
15 | 李政,王哲,倪维斗 .循环流化床全工况实时动态数学模型的研究[J].动力工程,2000,20(1):511-514. doi:10.3969/j.issn.1674-7607.2000.01.002 |
LI Z, WANG Z, NI W D .Study of full working scope dynamic mathematical model for CFBC[J].Power Engineering,2000,20(1):511-514. doi:10.3969/j.issn.1674-7607.2000.01.002 | |
16 | GAO M M, HONG F, LIU J Z .Investigation on energy storage and quick load change control of subcritical circulating fluidized bed boiler units[J].Applied Energy,2017,185. doi:10.1016/j.apenergy.2016.10.140 |
17 | 高明明,岳光溪,雷秀坚,等 .超临界CFB锅炉主蒸汽压力控制系统研究[J].动力工程学报,2015,35(8):625-631. doi:10.3969/j.issn.1674-7607.2015.08.004 |
GAO M M, YUE G X, LEI X J,et al .Research on main steam pressure control of supercritical CFB boilers[J].Journal of Chinese Society of Power Engineering,2015,35(8):625-631. doi:10.3969/j.issn.1674-7607.2015.08.004 | |
18 | 刘吉臻,洪烽,高明明,等 .循环流化床机组快速变负荷运行控制策略研究[J].中国电机工程学报,2017,37(14):4130-4137. doi:10.13334/j.0258-8013.pcsee.161055 |
LIU J Z, HONG F, GAO M M,et al .Research on the control strategy for quick load change of circulating fluidized bed boiler units[J].Proceedings of the CSEE,2017,37(14):4130-4137. doi:10.13334/j.0258-8013.pcsee.161055 | |
19 | ZHANG H F, GAO M M, FENG H,et al .Control-oriented modelling and investigation on quick load change control of subcritical circulating fluidized bed unit[J].Applied Thermal Engineering,2019,163:1-12. doi:10.1016/j.applthermaleng.2019.114420 |
20 | STEFANITSIS D, NESIADIS A, NIKOLOPOULOS A,et al .Simulation of a circulating fluidized bed power plant integrated with a thermal energy storage system during transient operation[J].Journal of Energy Storage,2021,43:1-17. doi:10.1016/j.est.2021.103239 |
21 | DENG B Y, ZHANG M, LYU J F,et al .Analysis on the safety of the water wall in a 350 MW supercritical cfb boiler under electricity failure condition[J].Energy,2019,189:116364. doi:10.1016/j.energy.2019.116364 |
22 | 韩小华,黄浩天,闫希晔,等 .大体积混凝土内部温度控制与现场测温差异分析[J].建筑技术,2022,53(8):1094-1097. doi:10.3969/j.issn.1000-4726.2022.08.035 |
HAN X H, HUANG H T, YAN X Y,et al .Analysis of difference between internal temperature control and on-site temperature measurement of mass concrete[J].Architecture Technology,2022,53(8):1094-1097. doi:10.3969/j.issn.1000-4726.2022.08.035 | |
23 | 张絮涵 .混凝土埋管式辐射冷顶板室内非稳态换热特性研究[D].长沙:湖南大学,2016. doi:10.1016/j.buildenv.2015.11.006 |
ZHANG X H .Research on the characteristics of non-steady state heat transfer in the room with concrete ceiling radiant cooling panels[D].Changsha:Hunan University,2016. doi:10.1016/j.buildenv.2015.11.006 | |
24 | RAFIQUE M M, NATHAN G,SAW W .A mathematical model to assess the influence of transients on a refractory-lined solar receiver[J].Renewable Energy,2021,167(C):217-235. doi:10.1016/j.renene.2020.11.077 |
25 | RAFIQUE M M, NATHAN G,SAW W .Modelled annual thermal performance of a 50 MW refractory-lined particle-laden solar receiver operating above 1 000 ℃[J].Renewable Energy,2022,197:168-175. doi:10.1016/j.renene.2022.07.111 |
26 | RAFIQUE M M, NATHAN G,SAW W .Thermal response of multilayered refractory-lined solar receivers to transient operation[J].Solar Energy,2022,243:352-361. doi:10.1016/j.solener.2022.07.037 |
27 | QI G L, LIU X M, WANG Z W,et al .Numerical simulation and optimization of heat-insulation material and structure for CFB boiler[J].Thermal Science and Engineering Progress,2020,20(12):100692. doi:10.1016/j.tsep.2020.100692 |
28 | FENG H J, CHEN L G, XIE Z H,et al .Constructal designs for insulation layers of steel rolling reheating furnace wall with convective and radiative boundary conditions[J].Applied Thermal Engineering,2016,100:145-152. doi:10.1016/j.applthermaleng.2016.02.129 |
29 | ZHOU X H, NIU T T, XIN Y F,et al .Experimental and numerical investigation on heat transfer in the vertical upward flow water wall of a 660 MW ultra-supercritical CFB boiler[J].Applied Thermal Engineering,2021,188:169-178. doi:10.1016/j.applthermaleng.2021.116664 |
30 | PAN J, WU G, YANG D .Thermal-hydraulic calculation and analysis on water wall system of 600 MW supercritical CFB boiler[J].Applied Thermal Engineering,2015,82:225-236. doi:10.1016/j.applthermaleng.2015.03.004 |
31 | LI J, TUNG Y, KWAUK M .Energy transport and regime transition in particle-fluid two-phase flow[C]//Proceedings of the Second International Conference on Circulating Fluidized Beds,Compiégne,France.1988:75-87. doi:10.1016/b978-0-08-036225-0.50012-5 |
32 | 黄永志 .循环流化床锅炉水动力特性研究[D].上海:上海交通大学,2016. |
HUANG Y Z .Research on water circulation characteristics of evaporating system in CFB boiler[D].Shanghai:Shanghai Jiaotong University,2016. | |
33 | 张宏涛,徐冰,白玉星,等 .钢混凝土界面接触热阻试验研究[J].土木建筑与环境工程,2015,37(2):34-38. doi:10.11835/j.issn.1674-4764.2015.02.006 |
ZHANG H T, XU B, BAI Y X,et al .Experiment alanalysis of interface thermal contact resistance between steel and concrete[J].Journal of Civil, Architectural & Environmental Engineering,2015,37(2):34-38. doi:10.11835/j.issn.1674-4764.2015.02.006 |
[1] | Xiaofeng CHEN, Chuan ZUO, Ning ZHAO, Kai HUANG, Huijie WANG. Analysis on Peak Regulation Characteristics of Thermal Power Units With Integrated Heat Storage Device [J]. Power Generation Technology, 2024, 45(3): 392-400. |
[2] | Qigang DENG, Zhuo LÜ, You SHI, Jiayi LU, Xu ZHOU, Aoyu WANG, Dong YANG. Safety Calculation and Analysis of Water Wall for a 700 MW Ultra-Supercritical Circulating Fluidized Bed Boiler Without External Bed After Power Failure [J]. Power Generation Technology, 2024, 45(2): 240-249. |
[3] | Songyuan YU, Junsong ZHANG, Zhiwei YUAN, Fang FANG. Resilience Enhancement Strategy of Combined Heat and Power-Virtual Power Plant Considering Thermal Inertia [J]. Power Generation Technology, 2023, 44(6): 758-768. |
[4] | Hongjian WANG, Haiyang WANG, Hao KONG, Tuo ZHOU, Man ZHANG, Hairui YANG. Retrofitting Strategy and Operating Technology of Pure Burning Zhundong Coal in a 135 MW Circulating Fluidized Bed Boiler [J]. Power Generation Technology, 2022, 43(6): 918-926. |
[5] | Xiufeng YAN, Ke ZONG, Xiunian HE, Lin GAO, Bin QIN, Mingkun WANG, Wentao HUI. Research on Steam Temperature Control Strategy in Peak Regulation of 1 000 MW Coal Power Unit [J]. Power Generation Technology, 2022, 43(3): 518-522. |
[6] | Xiankui WEN,Shihai ZHAGN,Tongtian DENG,Pan LI,Wen CHEN. A Summary of Large Capacity Power Energy Storage Peak Regulation and Frequency Adjustment Performance [J]. Power Generation Technology, 2018, 39(6): 487-492. |
[7] | Jiang TANG,Xuedong WANG,Yuzhu ZHAO,Chuanwu YAN. Analysis of Performance Indicators and Peak Regulation Capacity of Condensing Unit After High Back Pressure Retrofit for Heating [J]. Power Generation Technology, 2018, 39(5): 455-461. |
[8] | Shuming LI,Qingsong LIU,Xiaodong ZHU,Shibin PING,Guisheng BAI. Flexibility Transformation Analysis of 350 MW Supercritical Cogeneration Unit [J]. Power Generation Technology, 2018, 39(5): 449-454. |
[9] | Gaosheng WEI,Yao WANG,Yanping YANG,Chao XU,Xiaoze DU. Pore-Scale Numerical Simulation of Heat Transfer Enhancement of Phase Change Thermal Energy Storage Materials With Porous Foam Metals [J]. Power Generation Technology, 2018, 39(2): 158-164. |
[10] | Xiaojuan HAN,Yaoyao AI,Xiangjun LI. Application Value of Energy Storage Systems in the Power Grid and Its Commercial Modes [J]. Power Generation Technology, 2018, 39(1): 77-83. |
Viewed | ||||||
Full text |
|
|||||
Abstract |
|
|||||