Power Generation Technology ›› 2017, Vol. 38 ›› Issue (1): 21-24.DOI: 10.3969/J.ISSN.2095-3429.2017.01.005
Previous Articles Next Articles
CHANG Zheng, ZHANG Zhen-hua, ZHAO Wen-bo, WAN Kui-fang, GAO Zhi-pu
Received:
Revised:
Published:
Online:
Abstract: Increasing parameters for subcritical units upgrade is a hot issue recently as well as cross-generation. By technical and economic comparison between these two retrofitting programs, the result for 600 MW wet cooling subcritical unit shows that the former can reduce coal consumption to 298.67g/(k W·h) while the latter 277.3g/(k W·h). However,parameter-increase scheme has more advantages such as small retrofitting scale, short duration and also cost few
Key words: increasing parameters, cross-generational upgrade, turbine retrofitting
CLC Number:
TM621
CHANG Zheng, ZHANG Zhen-hua, ZHAO Wen-bo, WAN Kui-fang, GAO Zhi-pu. Upgrade Scheme Comparison Between Parameter-increase and CrossGeneration for Subcritical Units[J]. Power Generation Technology, 2017, 38(1): 21-24.