Power Generation Technology ›› 2017, Vol. 38 ›› Issue (3): 14-17,13.DOI: 10.3969/J.ISSN.2095-3429.2017.03.004

Previous Articles     Next Articles

Reason Analysis and Treatment for Cracking in Reheater Attemperator

CHEN Shi-ling   

  1. Hangzhou Huadian Banshan Power Generation Co., Ltd, Hangzhou 310015, China
  • Received:2017-03-24 Revised:2017-05-15 Published:2017-06-30 Online:2017-06-30

Abstract: The inspection of reheater attemperator is an important part of routine maintenance of gas turbine.This article described the water inlet pipe of desuperheater weld crack phenomenon found in the routine maintenance of 6 gas turbine,and analyzed the reason of desuperheater weld cracking and fracture. On one of the gas turbine desuperheater,the inlet pipe and the heat exchanger casing structure were improved. After more than 2 years of operation,it's currently running in good condition.

Key words: mechanical atomizing desuperheater, hybrid attemperator, fatigue failure, 1,2 communicating pipe of the reheater, cracking

CLC Number: