Thermal Deviation Detection Method for Heat Transfer Surfaces in a 660 MW Opposed-Firing Boiler Based on Historical Operation Data and Euclidean Distance
Power Generation Technology   Pages: 1-9(2026)
Updated:2026-06-30
  • Export

  • Collection

  • Album

    • Thermal Deviation Detection Method for Heat Transfer Surfaces in a 660 MW Opposed-Firing Boiler Based on Historical Operation Data and Euclidean Distance

    • “Under the national 'carbon peak and carbon neutrality' strategic goals, coal-fired power generation units frequently participate in deep peak shaving. A team explored the real-time discrimination of boiler thermal deviation and established a thermal deviation index system based on Euclidean distance, providing a solution to the problem of delayed warning of water wall overheating.”
    • DOI:10.12096/j.2096-4528.pgt.25469    

      CLC:
    • Revised:2026-02-20,

    Scan QR Code

  •  
  •  

35

Views

23

Downloads

0

CSCD

Alert me when the article has been cited
Submit
Outline

Related Articles

Thermodynamic Analysis of Carbon Capture Coal-Fired Cogeneration System Integrated With Compressed Carbon Dioxide Energy Storage
Autoencoder-Based Modeling for Fouling Monitoring on Boiler Heating Surfaces
Research on Performance Optimization of Transient Load Change Process in Coal-Fired Power Units
Analysis of Influence of Flue Gas Recirculation on Thermodynamic Performance and Economic Efficiency of 125 MW Supercritical CO2 Coal-Fired Power Generation Unit
Effects of Variable-Flow Water Distribution on Cooling Performance of Wet Cooling Towers and Its Optimization

Related Author

YAN Junjie
LIU Ming
YANG Kaibo
CHEN Gang
FANG Qingyan
ZHANG Cheng
WANG Ke
TAN Peng

Related Institution

School of Energy and Power Engineering, Xi’an Jiaotong University
Department of Thermal Energy and Power Engineering, School of Energy and Power Engineering, Huazhong University of Science and Technology
Shanghai Special Equipment Supervision and Inspection Institute, Putuo District
State Key Laboratory of Multiphase Flow in Power Engineering, Xi’an Jiaotong University
China Energy Digital Technology Group Co., Ltd., Chaoyang District