考虑天气影响的火电机组空冷系统性能预测方法
董建宁, 安吉振, 陈衡, 潘佩媛, 徐钢, 王修彦

Performance Prediction Method for Air Cooling System of Thermal Power Unit Considering Weather Effect
Jianning DONG, Jizhen AN, Heng CHEN, Peiyuan PAN, Gang XU, Xiuyan WANG
表2 去除各项特征后拟合优度对比
Tab. 2 Comparison of R2 after removing each feature
参数时间/min
51015202530354045505560
原测试集0.950.950.940.930.920.910.890.870.850.830.810.78
去大气压0.970.970.960.960.950.930.920.900.890.870.850.82
去温度0.940.930.910.900.890.880.870.850.850.830.820.80
去风速0.940.940.920.920.910.890.870.850.830.810.780.76
去风向0.960.950.940.940.920.910.890.870.860.830.810.78
去排汽压力0.900.900.870.860.850.820.780.760.730.700.660.63
去排汽温度0.940.930.910.900.880.860.830.810.770.750.720.68
去主汽压力0.940.940.930.930.920.910.890.880.860.840.820.80
去主汽温度0.960.950.940.940.920.910.890.880.860.830.810.79
去风机转速0.930.930.920.920.910.890.870.860.850.830.810.79
去主汽流量0.960.960.950.940.930.920.910.890.880.850.830.81
去给水流量0.960.960.940.940.930.910.890.880.860.840.820.79
去凝器真空0.870.880.870.870.860.850.850.830.830.800.780.77
去凝结水流量0.940.940.930.920.910.900.880.870.850.830.810.79
去凝结水温度0.940.930.920.920.910.900.880.860.850.830.800.78