表4 模型计算结果
Tab. 4 Model calculation results
方案能源利用率/%㶲效率/%
5 MW供热

50%

供热

原最大供热5 MW供热

50%

供热

原最大供热
#1案例27.5041.4959.1524.8128.6733.55
#1低零改造26.5141.1059.0523.7527.9733.31
#1高背改造23.2838.8958.6718.5723.7930.43
#1热泵改造29.1343.4561.5923.0827.0332.04
#2案例38.1647.9962.6833.8635.0336.69
#2低零改造34.2844.8560.8429.9131.9334.99
#2高背改造30.7040.9256.2131.2132.8135.23
#2热泵改造40.2450.0064.6232.9534.1135.87
#3案例38.0347.9262.1134.3135.4236.90
#3低零改造23.4736.8656.0919.7724.3931.03
#3高背改造36.2446.5461.2832.4133.9736.12
#3热泵改造38.2648.0462.4534.2335.3536.85