集成蓄热装置的火电机组调峰特性分析
|
陈晓峰, 左川, 赵宁, 黄凯, 王惠杰
|
Analysis on Peak Regulation Characteristics of Thermal Power Units With Integrated Heat Storage Device
|
Xiaofeng CHEN, Chuan ZUO, Ning ZHAO, Kai HUANG, Huijie WANG
|
|
表2 11月份电负荷优化输出结果前后对比
|
Tab. 2 Comparison of output results of electricity load optimization in November
|
|
时刻 | 原始最低电负荷/MW | 优化后最低电负荷/MW | 时刻 | 原始最低电负荷/MW | 优化后最低电负荷/MW |
---|
01:00 | 173.16 | 141.01 | 13:00 | 142.35 | 140.25 | 02:00 | 176.68 | 140.59 | 14:00 | 140.46 | 140.32 | 03:00 | 178.06 | 140.34 | 15:00 | 141.72 | 140.65 | 04:00 | 198.37 | 246.52 | 16:00 | 142.98 | 141.89 | 05:00 | 199.38 | 247.14 | 17:00 | 151.65 | 140.45 | 06:00 | 199.44 | 244.63 | 18:00 | 151.78 | 141.61 | 07:00 | 210.76 | 258.80 | 19:00 | 159.64 | 140.45 | 08:00 | 209.63 | 250.27 | 20:00 | 159.76 | 140.36 | 09:00 | 184.48 | 141.89 | 21:00 | 187.62 | 230.52 | 10:00 | 165.61 | 141.12 | 22:00 | 185.10 | 227.97 | 11:00 | 141.09 | 140.42 | 23:00 | 171.90 | 140.25 | 12:00 | 141.72 | 140.21 | 24:00 | 172.53 | 141.36 |
|
|
|