集成蓄热装置的火电机组调峰特性分析
陈晓峰, 左川, 赵宁, 黄凯, 王惠杰

Analysis on Peak Regulation Characteristics of Thermal Power Units With Integrated Heat Storage Device
Xiaofeng CHEN, Chuan ZUO, Ning ZHAO, Kai HUANG, Huijie WANG
表1 不同功率的蓄热罐在不同热负荷下的调峰增量 (MW)
Tab. 1 Peak load increment of heat storage tank with different power under different heat loads
热负荷调峰增量

20 MW

蓄热罐

40 MW

蓄热罐

60 MW

蓄热罐

80 MW

蓄热罐

1353.456.9010.3413.79
1443.456.9010.3413.79
1535.869.3112.7516.20
16211.1514.6018.0521.49
17115.4720.0123.4626.91
18017.0525.5328.9832.43
18917.0531.4334.6238.07
19817.0533.0840.3743.82
20717.0533.0846.2149.65
21617.0533.0849.1055.65
22517.0533.0849.1061.61
23417.0533.0849.1064.13