1 000 MW超超临界燃煤锅炉深度调峰研究
|
|
丁湧
|
Research on Deep Peak Shaving Performance of 1 000 MW Ultra-Supercritical Coal-Fired Boiler
|
|
Yong DING
|
|
表6 烟气参数表盘值与实测值对比
|
Tab. 6 Comparison between flue gas parameter dial and actual measurement
|
|
| 工况 | 类别 | SCR入口烟温/℃ | SCR入口氧体积分数/% | NO x 质量浓度 (标态、干基、6%O2)/(mg/m3) | 排烟温度/℃ | 空预器出口氧体积分数/% |
|---|
| T-01 | 表盘值 | 343.9 | 7.3 | 162.4 | 151.5 | 8.91 | | 实测值 | 334.8 | 7.7 | 210.5 | 155.7 | 9.38 | | T-02 | 表盘值 | 346.6 | 7.05 | 148.1 | 147.5 | 8.79 | | 实测值 | 345.9 | 7.45 | 195.2 | 144.4 | 9.06 | | T-03 | 表盘值 | 343.7 | 6.31 | 143.7 | 146.8 | 8.24 | | 实测值 | 341.7 | 6.43 | 182.1 | 146.7 | 7.73 | | T-04 | 表盘值 | 341.9 | 6.55 | 193.2 | 145.5 | 8.39 | | 实测值 | 341.6 | 6.63 | 255.0 | 147.7 | 7.79 |
|
|
|