表2 案例机组THA工况模型检验
Tab. 2 Condition model test of case unit THA
参数THA模型误差
主汽温度/℃5385380.00
主汽压力/MPa16.716.70.00
主汽流量/(t/h)1 872.51 872.50.00
再热蒸汽流量/(t/h)1 569.61 569.60.00
小汽机进汽流量/(t/h)65.20165.62-0.419
一抽压力/MPa6.1086.1080.00
二抽压力/MPa3.6923.725-0.033
三抽压力/MPa1.6681.6680.00
四抽压力/MPa0.7660.7650.001
五抽压力/MPa0.3150.3150.00
六抽压力/MPa0.1240.1240.00
七抽压力/MPa0.0550.0550.00
八抽压力/MPa0.0190.0190.00
一抽流量/(t/h)141.587140.0421.545
二抽流量/(t/h)153.056155.377-2.321
三抽流量/(t/h)76.30776.2940.013
四抽流量/(t/h)77.18378.984-1.801
五抽流量/(t/h)70.60070.5090.091
六抽流量/(t/h)51.17151.453-0.282
七抽流量/(t/h)56.90256.0250.877
八抽流量/(t/h)55.80357.341-1.538
排汽压力/MPa0.0040.0040.00
发电功率/MW630630.102-0.102