660 MW核电机组一次调频实验及动态特性仿真分析
唐平

Experiment and Dynamic Characteristics Simulation of Primary Frequency Regulation of a 660 MW Nuclear Power Unit
Ping TANG
表5 660 MW平台扰动试验期间动态响应指标
Tab. 5 Dynamic response indexes of 660 MW platform during disturbance test
负荷变化/%要求值峰值稳定值动作死区值/Hz调差系数/%
功率/MW响应时间/s功率/MW响应时间/s功率/MW响应时间/s峰值稳定值
3679.62.5686.910683.028-0.0674.425.16
-3640.545.0639.850639.9500.0675.865.89
2673.22.7677.410673.942-0.0674.565.70
-2646.839.0645.949645.9580.0675.615.63
1665.43.0666.625666.748-0.0676.005.90
-1679.62.5686.910683.0280.0675.955.60