660 MW核电机组一次调频实验及动态特性仿真分析
唐平

Experiment and Dynamic Characteristics Simulation of Primary Frequency Regulation of a 660 MW Nuclear Power Unit
Ping TANG
表4 594 MW平台扰动试验期间机组参数变化
Tab. 4 Changes of unit parameters during disturbance test of 594 MW platform
负荷变化/%模拟转速偏差/(r/min)负荷预计变化/MW负荷实际变化/MW调门开度变化/%D棒变化
-15.8-6.6-738.4→37.5185→183
1-5.86.6838.4→39.4186→187
-27.6-13.2-1338.4→36.7193→186
2-7.613.21538.5→40.7183→188
-39.4-19.8-1938.5→36.1192→184
3-9.419.82238.9→42.5189→201