660 MW核电机组一次调频实验及动态特性仿真分析
|
唐平
|
Experiment and Dynamic Characteristics Simulation of Primary Frequency Regulation of a 660 MW Nuclear Power Unit
|
Ping TANG
|
|
表3 594 MW平台扰动试验期间动态响应指标
|
Tab. 3 Dynamic response indices of 594 MW platform during disturbance test
|
|
负荷变化/% | 要求值 | 峰值 | 稳定值 | 动作死区值/Hz | 调差系数/% |
---|
功率/MW | 响应时间/s | 功率/MW | 响应时间/s | 功率/MW | 响应时间/s | 峰值 | 稳定值 |
---|
3 | 611.8 | 4.4 | 616.6 | 34.1 | 616.1 | 61.1 | -0.067 | 4.74 | 4.84 | -3 | 576.2 | 12.0 | 574.2 | 38.0 | 574.7 | 46.0 | 0.067 | 5.40 | 5.53 | 2 | 605.9 | 1.9 | 609.8 | 15.8 | 608.1 | 54.1 | -0.067 | 4.50 | 5.06 | -2 | 582.1 | 11.0 | 581.3 | 32.0 | 580.5 | 62.0 | 0.067 | 5.63 | 5.28 | 1 | 599.9 | 3.2 | 602.6 | 11.8 | 601.4 | 44.0 | -0.067 | 4.13 | 4.80 | -1 | 588.1 | 2.2 | 586.8 | 38.2 | 587.6 | 60.2 | 0.067 | 4.95 | 5.59 |
|
|
|