660 MW核电机组一次调频实验及动态特性仿真分析
唐平

Experiment and Dynamic Characteristics Simulation of Primary Frequency Regulation of a 660 MW Nuclear Power Unit
Ping TANG
表3 594 MW平台扰动试验期间动态响应指标
Tab. 3 Dynamic response indices of 594 MW platform during disturbance test
负荷变化/%要求值峰值稳定值动作死区值/Hz调差系数/%
功率/MW响应时间/s功率/MW响应时间/s功率/MW响应时间/s峰值稳定值
3611.84.4616.634.1616.161.1-0.0674.744.84
-3576.212.0574.238.0574.746.00.0675.405.53
2605.91.9609.815.8608.154.1-0.0674.505.06
-2582.111.0581.332.0580.562.00.0675.635.28
1599.93.2602.611.8601.444.0-0.0674.134.80
-1588.12.2586.838.2587.660.20.0674.955.59