660 MW核电机组一次调频实验及动态特性仿真分析
唐平

Experiment and Dynamic Characteristics Simulation of Primary Frequency Regulation of a 660 MW Nuclear Power Unit
Ping TANG
表2 528 MW平台扰动试验期间机组参数变化
Tab. 2 Changes of unit parameters during disturbance test of 528 MW platform
负荷变化/%模拟转速偏差/(r/min)负荷预计变化/MW负荷实际变化/MW调门开度变化/%D棒变化
-15.8-6.6-733.6→32.9191→188
1-5.86.6633.8→34.5188→190
-27.6-13.2-1533.8→32.4190→184
2-7.613.21434.0→35.4186→193
-39.4-19.8-2133.4→31.7190→182
3-9.419.82033.9→35.9186→195