表1 528 MW平台扰动试验期间动态响应指标
Tab. 1 Dynamic response indices of 528 MW platform during disturbance test
负荷变化/%要求值峰值稳定值动作死区值/Hz调差系数/%
功率/MW响应时间/s功率/MW响应时间/s功率/MW响应时间/s峰值稳定值
3543.88.5547.836.0547.438.0-0.0674.784.88
-3512.04.2507.038.5507.346.00.0674.574.59
2538.53.6542.040.1541.950.0-0.0674.474.56
-2517.45.6513.040.1514.052.10.0674.354.54
1533.23.6534.47.9534.114.7-0.0674.955.22
-1522.73.1520.75.3521.410.90.0674.354.80